Especially for gases with high requirements on purity up to 6.0 and for laboratories and analytics. In case of our special cleaning method the cylinder pressure regulator is ECD capable.
The stainless steel version with viton elasto- mers allows the usage of aggressive gases.
We recommend to prefix a fine filter with max. 40 μ at the inlet and an installation of suitable safety valves to protect downstream equipment from improper high pressures.
To identify the correct order code for your HP320
Start with "HP320-", then add the appropriate number options from columns A, B, C, D & E in the table below followed by the gas to be used.
HP320-1-1-3-1-2-Argon specifies a HP320 model in stainless steel with left to right inlet, 10-200 bar outlet pressure ranges, with guages & 6mm compression fitting inlet and outlets, for use with Argon gas.
A |
B
|
C
|
D
|
E
|
Material |
Inlet |
Outlet pressure ranges |
Gauges |
Option for inlet and outlet |
1 = stainless steel
|
1 = left to the right |
1 = 5 - 50 bar |
1 = with gauge |
1 = 1/4“ NPT – international thread |
2 = brass |
2 = right to the left |
2 = 5 - 100 bar |
2 = without gauges |
2 = compression fitting 6 mm |
|
|
3 = 10 - 200 bar |
|
3 = compression fitting 8 mm |