The dome pressure regulator is used as a line pressure regulator. Without exchanging parts it is suitable for a large outlet pressure range.
Independent of the used material the pressure regulator is applicable for different gases and liquids.
Urgently recommend the connection of a fine filter, with at least 40 μ, before the pressure regulator, to protect following components with suitable relief valves against unduly high pressures.
To identify the correct order code for your Pilot D1
Start with the regulator type (36P in this case) then add the appropriate number options from columns A, B, C, D, E & F in the table below followed by the gas to be used.
36P-1-0-1-0-0-0-Argon specifies a Pilot DH1 model in brass with 100 bar pressure, Ø 6.35 seat, EPDM diaphragm, no gauges, no optional solenoid valve & G 1" female part inlet/outlet, for use with Argon gas.
A |
B |
C |
D |
E |
F |
Material / Pressure |
Seat |
Diaphragm |
Gauges |
Optional Solenoid Valve |
Inlet/Outlet Options |
1 = brass / 100 bar |
0= Ø 6.35 |
1 = EPDM |
0 = none |
0= without |
0 = G1" f |
2 = stainless steel / 100 bar |
1 = Ø 12.7 (balanced) |
2 = viton |
1 = with inlet and outlet gauges |
1 = 24 V |
1 = flange DN25-PN40-Form C |
3 = brass / 5 bar |
|
|
|
2 = 230 V |
|
4 = stainless steel / 5 bar |
|
|
|
|
|